Okuma Alarm P-0826 – Axis Construction Data File Read Error

Alarm P-0826 indicates that the axis construction parameter file (SAXD*.PBU) cannot be found or read from the MDO directory.

This means the CNC control is unable to load the required axis configuration data during startup or initialization.

Common causes include:

  • Missing SAXD*.PBU file in the MDO folder

  • Corrupted axis construction data file

  • Incorrect software installation or update

  • Incomplete data backup restoration

  • Memory or storage failure

The machine cannot correctly initialize axis parameters without this file.

Recommended actions:

  1. Verify that the SAXD*.PBU file exists in the MDO directory.

  2. Check file integrity and size.

  3. Reload axis construction data from backup.

  4. Confirm correct software version.

  5. Inspect storage device for errors.

If the file is lost and no backup is available, axis parameters must be restored from machine documentation or manufacturer data.