Okuma Alarm A-8649 – Measurement Sensor Unit Interlock
Alarm A-8649 indicates that movement of the measurement sensor unit is inhibited due to an interlock condition.
This alarm occurs when:
-
A movement command is issued while the measurement sensor unit is in a locked or non-movable state, or
-
An abnormal condition is detected during movement that makes continued motion unsafe.
The measurement sensor unit (such as a tool setter, probe arm, or in-process measurement device) is protected by interlock logic to prevent mechanical damage.
When this alarm appears:
-
The sensor unit cannot extend or retract
-
The control detects an invalid movement state
-
The machine prevents further motion to avoid collision or hardware damage
Possible causes include:
-
Mechanical obstruction
-
Sensor unit not in home position
-
Limit switch or position sensor fault
-
Interlock signal active
-
Air pressure insufficient (for pneumatic units)
-
PLC logic condition not satisfied
Recommended actions:
-
Check that the measurement unit is free of obstruction.
-
Verify home position and limit switch signals.
-
Inspect pneumatic pressure (if applicable).
-
Check wiring and I/O signals related to the unit.
-
Reset the alarm and reinitialize the unit.
This alarm is a protective interlock and is intended to prevent mechanical damage to the measurement system.