Okuma Alarm A-1107 – Major FL-net Error

Alarm A-1107 indicates a critical failure during initialization of the FL-net communication card.

FL-net (Factory Local Network) is the industrial communication network used for high-speed data exchange between the CNC, PLC, and other control units. When this alarm appears, the FL-net interface failed to start correctly or detected a fatal communication fault.

As a result:

  • Communication between CNC and PLC may be interrupted

  • Loader or peripheral devices may not respond

  • Machine startup may be incomplete

  • Network-dependent functions may be disabled

Possible causes include:

  • FL-net board hardware failure

  • Initialization error during power-up

  • Corrupted firmware

  • Network configuration mismatch

  • Loose or damaged communication cable

  • Power supply instability

Recommended actions:

  1. Power off the machine completely and restart.

  2. Check FL-net board LEDs for abnormal status.

  3. Inspect network cables and connectors.

  4. Verify network parameters and node settings.

  5. Reseat or replace the FL-net card if necessary.

  6. Contact authorized service if the error persists.

Because this is classified as a “Major” error, normal operation may not be possible until the issue is resolved.