Okuma Alarm A-8647 – Hand Open/Close Switch NG
Alarm A-8647 indicates that the manual open/close operation was commanded, but the corresponding confirmation signal was not received within the specified time set in the machine parameters.
In simple terms, the control issued a hand open or hand close command (for example, chuck, door, tailstock, or other actuator), but the expected feedback signal did not return.
This alarm occurs when:
-
A manual open/close command is executed
-
The output signal is sent correctly
-
The status input (confirmation signal) does not match
-
The response time exceeds the parameter-defined limit
Possible causes include:
-
Faulty open/close limit switch
-
Defective proximity sensor
-
Broken wiring or loose connector
-
PLC input/output mismatch
-
Incorrect parameter timing setting
-
Mechanical obstruction preventing full movement
When this alarm appears, the machine blocks further operation to prevent unsafe movement or mechanical damage.
Recommended actions:
-
Check the mechanical movement of the device (is it actually opening/closing?).
-
Inspect limit switches and proximity sensors.
-
Verify PLC I/O signals in the diagnostic screen.
-
Check wiring and connectors.
-
Confirm parameter time settings for open/close monitoring.
This is typically an interlock or feedback problem, not a CNC software issue.