Okuma Alarm A-8647 – Hand Open/Close Switch NG

Alarm A-8647 indicates that the manual open/close operation was commanded, but the corresponding confirmation signal was not received within the specified time set in the machine parameters.

In simple terms, the control issued a hand open or hand close command (for example, chuck, door, tailstock, or other actuator), but the expected feedback signal did not return.

This alarm occurs when:

  • A manual open/close command is executed

  • The output signal is sent correctly

  • The status input (confirmation signal) does not match

  • The response time exceeds the parameter-defined limit

Possible causes include:

  • Faulty open/close limit switch

  • Defective proximity sensor

  • Broken wiring or loose connector

  • PLC input/output mismatch

  • Incorrect parameter timing setting

  • Mechanical obstruction preventing full movement

When this alarm appears, the machine blocks further operation to prevent unsafe movement or mechanical damage.

Recommended actions:

  1. Check the mechanical movement of the device (is it actually opening/closing?).

  2. Inspect limit switches and proximity sensors.

  3. Verify PLC I/O signals in the diagnostic screen.

  4. Check wiring and connectors.

  5. Confirm parameter time settings for open/close monitoring.

This is typically an interlock or feedback problem, not a CNC software issue.