Okuma Alarm A-1112 – Non-Functioning Device Detected

Alarm A-1112 indicates that the control system has detected a connected device that is not responding or not operating correctly.

The CNC recognizes a hardware unit, but it cannot communicate with it properly or retrieve valid operational data. In some cases, the installed software does not support the detected device configuration.

Possible causes include:

  • Hardware failure of the connected device

  • Communication interruption (cable, interface, I/O board)

  • Incorrect device configuration

  • Software version mismatch

  • Unsupported or newly installed component

This alarm prevents machine operation to avoid unsafe or undefined behavior.

Recommended actions:

  1. Verify physical connections and wiring.

  2. Check communication interfaces and I/O modules.

  3. Confirm device configuration in parameters.

  4. Ensure CNC software supports the installed hardware.

  5. Restart the control system after inspection.

If the problem remains, hardware diagnostics of the affected unit is required.