Okuma Alarm A-1109 – Error Occurred During CAS Operation
Alarm A-1109 indicates that an internal error occurred within the CAS (Collision Avoidance System) software.
CAS is responsible for virtual machine simulation, interference detection, and model-based collision prevention. When this alarm appears, CAS processing has stopped due to a software or calculation fault.
As a result:
-
Interference detection may be disabled
-
3D model display may not function correctly
-
Virtual machine simulation may stop
-
Collision monitoring may be inactive
Possible causes include:
-
CAS software malfunction
-
Corrupted machine model data
-
Invalid geometry or tool data
-
Parameter inconsistency
-
Software version incompatibility
Machine operation may continue, but collision avoidance functionality may be limited or unavailable.
Recommended actions:
-
Restart the control system.
-
Verify CAS model and machine data.
-
Check tool and workpiece geometry settings.
-
Reload CAS data if available.
-
Confirm software version compatibility.
If the error persists, CAS software diagnostics or update may be required.