Okuma Alarm A-1106 – FL-net Initialization Error

Alarm A-1106 indicates that an error occurred during initialization of the FL-net communication system.

FL-net (Factory Local Network) is used for high-speed communication between CNC, PLC, and other control modules. During power-up, the system attempts to initialize the FL-net interface. If this startup sequence fails or does not complete correctly, Alarm A-1106 is triggered.

When this alarm appears:

  • Communication between CNC and PLC may not be established

  • Peripheral devices connected via FL-net may not respond

  • Machine startup may be incomplete

  • Network-dependent functions may remain inactive

Possible causes include:

  • Incorrect FL-net configuration parameters

  • Node address conflict

  • Communication timeout during startup

  • Firmware mismatch

  • Temporary power instability

  • Loose or damaged network cable

Recommended actions:

  1. Power off the machine completely and restart.

  2. Verify FL-net network settings and node numbers.

  3. Check communication cables and connectors.

  4. Inspect FL-net board status indicators (LED signals).

  5. Confirm firmware compatibility.

  6. If the error repeats, perform detailed diagnostics of the FL-net module.

Unlike A-1107 (Major FL-net Error), this alarm indicates a startup initialization problem and may sometimes be resolved by a simple restart.