Okuma Alarm A-1106 – FL-net Initialization Error
Alarm A-1106 indicates that an error occurred during initialization of the FL-net communication system.
FL-net (Factory Local Network) is used for high-speed communication between CNC, PLC, and other control modules. During power-up, the system attempts to initialize the FL-net interface. If this startup sequence fails or does not complete correctly, Alarm A-1106 is triggered.
When this alarm appears:
-
Communication between CNC and PLC may not be established
-
Peripheral devices connected via FL-net may not respond
-
Machine startup may be incomplete
-
Network-dependent functions may remain inactive
Possible causes include:
-
Incorrect FL-net configuration parameters
-
Node address conflict
-
Communication timeout during startup
-
Firmware mismatch
-
Temporary power instability
-
Loose or damaged network cable
Recommended actions:
-
Power off the machine completely and restart.
-
Verify FL-net network settings and node numbers.
-
Check communication cables and connectors.
-
Inspect FL-net board status indicators (LED signals).
-
Confirm firmware compatibility.
-
If the error repeats, perform detailed diagnostics of the FL-net module.
Unlike A-1107 (Major FL-net Error), this alarm indicates a startup initialization problem and may sometimes be resolved by a simple restart.