Okuma Alarm A-1094 – PLC Backup Data File Read Error
Alarm A-1094 indicates that the CNC control cannot read the PLC backup data file from memory.
The PLC backup data is either missing, corrupted, or inaccessible.
As a result, the control cannot properly restore PLC parameters during startup.
Common causes include:
-
Corrupted PLC backup file
-
Memory or storage failure
-
Power interruption during data write
-
Battery-related SRAM data loss
-
Incomplete software update
The machine may not operate correctly until the PLC data is restored.
Recommended actions:
-
Verify the PLC backup file in memory.
-
Reload PLC data from a valid backup.
-
Check memory device integrity.
-
Inspect control battery condition.
-
Restart the system after restoring data.
If no valid backup exists, PLC parameters must be reloaded from machine documentation or manufacturer data.