Okuma Alarm A-1094 – PLC Backup Data File Read Error

Alarm A-1094 indicates that the CNC control cannot read the PLC backup data file from memory.

The PLC backup data is either missing, corrupted, or inaccessible.
As a result, the control cannot properly restore PLC parameters during startup.

Common causes include:

  • Corrupted PLC backup file

  • Memory or storage failure

  • Power interruption during data write

  • Battery-related SRAM data loss

  • Incomplete software update

The machine may not operate correctly until the PLC data is restored.

Recommended actions:

  1. Verify the PLC backup file in memory.

  2. Reload PLC data from a valid backup.

  3. Check memory device integrity.

  4. Inspect control battery condition.

  5. Restart the system after restoring data.

If no valid backup exists, PLC parameters must be reloaded from machine documentation or manufacturer data.